Fall Risk Classification in Community-Dwelling Older Adults Using a Smart Wrist-Worn Device and the Resident Assessment Instrument-Home Care: Prospective Observational Study

TitleFall Risk Classification in Community-Dwelling Older Adults Using a Smart Wrist-Worn Device and the Resident Assessment Instrument-Home Care: Prospective Observational Study
Publication TypeJournal Article
Year of Publication2019
AuthorsYang Y, Hirdes JP, Dubin JA, Lee J
JournalJMIR aging
Volume2
Issue1
Paginatione12153-e12153
ISBN Number2561-7605
Accession Number31518278
KeywordsElderly, falls, InterRAI, machine learning, wearable devices
Abstract

BACKGROUND:  Little is known about whether off-the-shelf wearable sensor data can contribute to fall risk classification or complement clinical assessment tools such as the Resident Assessment Instrument-Home Care (RAI-HC). OBJECTIVE:  This study aimed to (1) investigate the similarities and differences in physical activity (PA), heart rate, and night sleep in a sample of community-dwelling older adults with varying fall histories using a smart wrist-worn device and (2) create and evaluate fall risk classification models based on (i) wearable data, (ii) the RAI-HC, and (iii) the combination of wearable and RAI-HC data. METHODS:  A prospective, observational study was conducted among 3 faller groups (G(0), G(1), G(2+)) based on the number of previous falls (0, 1, ≥2 falls) in a sample of older community-dwelling adults. Each participant was requested to wear a smart wristband for 7 consecutive days while carrying out day-to-day activities in their normal lives. The wearable and RAI-HC assessment data were analyzed and utilized to create fall risk classification models, with 3 supervised machine learning algorithms: logistic regression, decision tree, and random forest (RF). RESULTS:  Of 40 participants aged 65 to 93 years, 16 (40%) had no previous falls, whereas 8 (20%) and 16 (40%) had experienced 1 and multiple (≥2) falls, respectively. Level of PA as measured by average daily steps was significantly different between groups (P=.04). In the 3 faller group classification, RF achieved the best accuracy of 83.8% using both wearable and RAI-HC data, which is 13.5% higher than that of using the RAI-HC data only and 18.9% higher than that of using wearable data exclusively. In discriminating between {G(0)+G(1)} and G(2+), RF achieved the best area under the receiver operating characteristic curve of 0.894 (overall accuracy of 89.2%) based on wearable and RAI-HC data. Discrimination between G(0) and {G(1)+G(2+)} did not result in better classification performance than that between {G(0)+G(1)} and G(2+). CONCLUSIONS:  Both wearable data and the RAI-HC assessment can contribute to fall risk classification. All the classification models revealed that RAI-HC outperforms wearable data, and the best performance was achieved with the combination of 2 datasets. Future studies in fall risk assessment should consider using wearable technologies to supplement resident assessment instruments.

DOI10.2196/12153
Link

https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6716444/

Short TitleJMIR AgingJMIR Aging
Alternate JournalJMIR Aging